EJA118E-FMSCG-919DB-WA13C1SW00-BA25/KS26/X2/D4/M2W/T52 | Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter
EJA118E-FMSCG-919DB-WA13C1SW00-BA25/KS26/X2/D4/M2W/T52 | Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter

EJA118E-FMSCG-919DB-WA13C1SW00-BA25/KS26/X2/D4/M2W/T52 | Yokogawa EJA118E Diaphragm Sealed Differential Pressure Transmitter

0 Review(s)
Availability: Estimated Lead Time: 8 - 9 Weeks
Part Number: EJA118E-FMSCG-919DB-WA13C1SW00-BA25/KS26/X2/D4/M2W/T52
USD2,829.00
Retail Price:USD4,041.00
You Save:USD1,212.00(30%)
Write a Review
Part Number: EJA118E-FMSCG-919DB-WA13C1SW00-BA25/KS26/X2/D4/M2W/T52
Model: EJA118E Diaphragm Sealed Differential Pressure Transmitter
Brand: Yokogawa
Condition: New & Original in Factory Packing
Factory Warranty: 12 Months

Description
The EJA-E series of transmitters is Yokogawa's most recent evolution of the DPharp family. Released in 2012, it combines the ruggedness and success of the work-horse EJA-E series with the performance of the thoroughbred EJX-A series to deliver the type of product you have come to expect from Yokogawa.

The EJA118E is a Differential Pressure Transmitter with remote diaphragm seals.

EJA118E features include:
  • ±0.2% Accuracy
  • 200 ms Response Time
  • Exida and TUV SIL2 / SIL3 Certified
  • Local Parameter Setting (LPS)
  • 10-segment Signal Characterizer
  • Active Capillary Fill Fluid Density Compensation

Model and Suffix Codes

Model EJA118E Diaphragm sealed differential pressure transmitter
Output signal -F Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)
Measurement span (capsule) M 2.5 to 100 kPa (10 to 400 inH2O)
S Always S
C Always C
Cover flange bolts and nuts material G 316L SST
Installation -9 Horizontal piping type and left side high pressure
Amplifier housing 1 Cast aluminum alloy
Electrical connection 9 M20 female, two electrical connections with a blind plug(1)
Integral indicator D Digital indicator(2)
Mounting bracket B 304 SST 2-inch pipe mounting, flat type (for horizontal piping)
Process connection style -W Flush type
Flange rating A1 ANSI class 150
Process connection size (Process flange size) 3 3-inch (80 mm)
Flange material C 316 SST(3)
Gasket contact surface(4) 1 Serration (for ANSI flange with wetted parts material SW only)
Wetted parts material(5) SW Diaphragm: 316L SST
Others: 316L SST
Flushing connection ring(6) *0 Ring: None
Vent/Drain plugs: -
Material: -
Extension 0 None
Fill fluid *-B For general use (silicone oil)
Process temperature: –30 to 180°C
Ambient temperature: –15 to 60°C
Capillary connection A Side of diaphragm seal unit
2 Always 2
Capillary length(7) 5 5 m
/KS26 Always 2
Painting /X2 Coating change: Anti-corrosion coating(8)
Calibration units(9)(10) /D4 M calibration (kgf/cmunit)
Material certificate /M2W Process flange, Block: For Flush type
Pressure test/Leak test certificate(11)(12) /T56 Flange rating: ANSI/JPI Class 300(13)
Test pressure: 8 MPa (1160 psi)

Nitrogen Gas(14) 
Retention time: one minute

The “*” marks indicate the most typical selection for each specification
  1. Material of a blind plug; aluminum alloy for code 5 and 9, and SUS304 for code 7.
  2. Not applicable for output signal code G.
  3. Forged version of the material may be used.
  4. See table 3 ‘Gasket contact surface’ on page 6.
  5. Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user’s process fluids.
    Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high temperature steam (150°C [302°F] or above). Contact Yokogawa for detailed information of the wetted parts material.
  6. When specified flushing connection ring code 1 or 2, exclusive gaskets are provided for transmitter side.
  7. In case of wetted parts material code HW (Hastelloy C) and TW (Tantalum) for 2-inch process flange, specify capillary length from 1 to 5m.
  8. Not applicable with color change option. Not applicable for amplifier housing code 2.
  9. The unit of MWP (Max. working pressure) on the name plate of a housing is the same unit as specified by option code D1, D3, and D4.
  10. Not applicable for Fill fluid code 1, 2, or 4.
  11. The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D4.
  12. A flushing connection ring will not be applied when conducting the pressure test or leak test.
  13. Applicable for flush type (process connection style code W.)
  14. Dry nitrogen gas is used for oil-prohibited use (option code K1 and K5.)


  • Estimated Lead Time: 8 - 9 Weeks
  • Shipping Weight: 15 Kg