YTA110-EA2DN/C1/KU2/D2 | Yokogawa Temperature Transmitter
YTA110-EA2DN/C1/KU2/D2 | Yokogawa Temperature Transmitter

YTA110-EA2DN/C1/KU2/D2 | Yokogawa Temperature Transmitter

0 Review(s)
Availability: Estimated Lead Time: 10 - 12 Weeks
Part Number: YTA110-EA2DN/C1/KU2/D2
USD631.00
Retail Price:USD901.00
You Save:USD270.00(30%)
Write a Review
Part Number: YTA110-EA2DN/C1/KU2/D2

Model and Suffix Codes
Model: YTA110Temperature Transmitter
Output Signal: -E 4 to 20mA DC with digital communication (HART protocol, refer to GS 01C50T01-00EN)
Always A
Electrical Connection: 1/2 NPT female
Integral Indicator: with digital indicator
Mounting Bracket: None

Option Codes:
/C1 -
Output signal low-side in Transmitter failure
Output signal low-side: -5%, 3.2 mA DC or less.
Sensor burnout is also set to 'LOW': -2.5%, 3.6 mA DC.

/KU2 -
ATEX
ATEX Intrinsically safe ia, Flameproof approval and Intrinsically safe ic combination
[Intrinsically safe ia approval]
     Applicable standard: EN 60079-0:2012, EN 60079-11:2012, EN 60079-26:2007
     Certificate: KEMA 02ATEX1026 X
     II 1 G Ex ia IIC T4...T5 Ga Ambient Temerature: -40 to 70?C for T4, -40 to 50?C for T5
     Enclosure: IP66/IP67
     Supply/Output circuit: Ui=30V, Ii=165mA, Pi=900mW, Ci=20nF, Li=730?H
     Input circuit: Uo=9V, Io=40mA, Po=90mW, Co=0.7?F, Lo=10mH
     Electrical Connection: 1/2 NPT female and M20 female?
[Flameproof and Dust Ignition Proof Approval]
     Applicable Standard: EN 60079-0: 2012+A11: 2013, EN 60079-1: 2007, EN 60079-31:2009
     Certificate: KEMA 07ATEX0130
     II 2 G Ex d IIC T6/T5 Gb, II 2 D Ex tb IIIC T70?C, T90?C Db
     Ambient Temperature for Gas Atmospheres: -40 to 75?C for T6, -40 to 80?C for T5
     Ambient Temperature for Dust Atmospheres: -30 to 65?C for T70?C, -30 to 80?C for T90?C
     Enclosure: IP66/IP67
     Electrical Connection: 1/2 NPT female and M20 female?
[Intrinsically safe ic]
     Applicable standard: EN 60079-0:2012, EN 60079-11:2012
     II 3 G Ex ic IIC T5...T4 Gc Ambient Temperature: -30 to 70?C for T4, -30 to 50?C for T5
     Enclosure: IP66/IP67
     Supply/Output circuit: Ui=30V, Ci=28nF, Li=730?H
     Input circuit: Uo=9V, Io=40mA, Po=90mW, Co=0.7?F, Lo=10mH
     Electrical connection: 1/2 NPT female and M20 female?

/D2 -
Calibration Unit
Degree F/Degree R unit

NOTE:
  1. Applicable for Electrical Connection Code 2 and 4.

  • Estimated Lead Time: 10 - 12 Weeks
  • Shipping Weight: 3 Kg