| Base Model | 266HSH | Gauge Pressure Transmitter BASE ACCURACY 0.06 % | |||||
| Sensor - Span Limits | V | 600 and 60000 kPa | 6 and 600 bar | 87 and 8700 psi | |||
| Diaphragm Material/Fill Fluid (wetted parts) | K | Hastelloy C-276? | Silicone oil | NACE | |||
| Process connection (wetted parts) | B | AISI 316 L ss | 1/2 ? 14 NPT-f female | NACE | |||
| Housing material and electrical connection | B | Aluminium alloy (barrel version) | M20 x 1.5 (CM 20) | ||||
| Output/Additional options | 1 | HART digital communication and 4 to 20 mA | Options requested by ?Additional ordering code?1 | ||||
| Hazardous area certifications | E2 | ATEX Explosion Proof Group II Category 1/2 G Ex d IIC T6 and Group II Category 1/2 D Ex tD A21 IP67 T85 °C² | |||||
| Integral LCD | L1 | Digital LCD integral display | |||||
| Additional tag plate | I2 | Laser printing of tag on stainless steel plate | |||||
| Material traceability | H3 | Inspection certificate EN 10204?3.1 of process wetted parts | |||||