| Rated capacity | 100 t |
| Limit load (with Lq = 0.15 x Ln) Limit load = Maximum admissible load |
210 t |
| Rupture load (with Lq = 0.15 x Ln) | 350 t |
| Max. admissible side load | 85 t |
| Sensitivity | 1.38 mV / V |
| Combined error | ±0.07 % |
| Creeping under load (30 min) | ±0.05 % |
| Input resistance | 690 ? + 6 ? |
| Output resistance | 700 ? + 4 ? |
| Reference supply voltage | 10 V |
| Max. supply voltage | 36 V |
| Nominal temperature range | -10 °C bis +100 °C |
| Service temperature range | -15 °C bis +150 °C |
| Reference temperature | +22 °C |
| Storage temperature range | -40 °C bis +180 °C |
| Temperature effect on zero signal | ±0.05 % / 10 K |
| Temperature effect on sensitivity | ±0.03 % / 10 K |
| Corrosion protection | hot dip galvanized |
| Protection class | IP65 |