| Model | EJX110A | Differential pressure transmitter |
| Output signal | -E | 4 to 20 mA DC with digital communication (HART 5 protocol) |
| Measurement span (capsule) | L | 0.1 to 10 kPa (0.4 to 40 inH2O)(For Wetted parts material code M, H, T, A, D,B and W) |
| Wetted parts material(1) | S# | Cover flange and process connector: ASTM CF-8M(2)(3) Capsule: Hastelloy C-276(4) (Diaphragm); F316L SST, 316L SST (Others) Capsule gasket: Teflon-coated 316L SST Vent/Drain plug: 316 SST |
| Process connections See the table in the next page for the codes for a diaphragm seal system |
4 | with 1/2 NPT female process connector |
| Bolts and nuts material | G | 316L SST |
| Installation | 9 | Horizontal piping and left side high pressure |
| Amplifier housing | 1 | Cast aluminum alloy |
| Electrical connection | 7 | 1/2 NPT female, two electrical connections and a blind plug(5) |
| Integral indicator | D | Digital indicator(6) |
| Mounting bracket | B | 304 SST 2-inch pipe mounting, flat type (for horizontal piping) |
| ATEX | /KU22 | Multiple types of protection (KF22, KS21 or Intrinsically safe Ex ic)(7)(8) Applicable Standard: EN IEC 60079-0, EN 60079-11 II 3 G Ex ic IIC T4 Gc, Amb. Temp.: –30 to 60°C (–22 to 140°F)(9) Ui=30 V, Ci=27.6 nF, Li=0 µH |
| Material certificate(10)(11) | /M11 | Cover flange, Process connector(12) |
| Pressure test/ Leak test certificate(11)(13) | /T12 | Test Pressure: 16 MPa(2300 psi)(14) Nitrogen gas(15) Retention time: one minute |