Model: IGP10 - I/A Series, Electronics, Direct Connected, High Gauge Pressure Transmitter¹
Electronics Versions and Output Signal: -T - Intelligent; Digital HART and 4 to 20 mA (Version -T)
Structure Code - Process Connection, Sensor, and Fill Fluid: 62 Connection Material:316L ss Sensor:316L ss Fill Fluid: Silicone
Span Limits - Absolute or Gauge Pressure Units, as Applicable: E MPa:0.07 and 2.1 psi: 10 and 300 bar: 0.7 and 21
Conduit Connection and Housing Material: 1 - 1/2 NPT Conduit Connection, Both Sides, Aluminum Housing
Electrical Safety (See "ELECTRICAL SAFETY SPECIFICATIONS"): G ATEX Certifications as follows: Version D and T; EEx nL IIC, Zone 2 Version F; FNICO EEx nL IIC, Zone 2
Refer to PSSs 2A-1C13A to 2A-1C13E for gauge pressure transmitter with span limits than 52 MPa (7500 psi). Refer to PSSs 2A-1C13K for IGP10 Transmitters with Sanitary Process Connections. Refer to PSSs 2A-1C13L for IGP10 Transmitters with Pulp and Paper Process Connections.